Published: 20.06.2025
See moreHow To Use Kosmen KM-30N Dehumidifier And Air Purifier

How To Use Kosmen KM-30N Dehumidifier!
Kosmen KM-30N Air Purifier & Dehumidifier User Manual
Kosmen KM-30N Air Purifier & Dehumidifier User Manual
Product Functions
The Kosmen KM-30N combines both air purification and dehumidification functions to offer optimal indoor air quality. Key features include:
Dehumidification
Controls and balances humidity levels in the room, preventing mold growth and protecting health and household furniture.
Air Purification
Equipped with a 3-layer filter system: Pre-filter – HEPA H13 – Activated Carbon, it effectively removes dust, odors, and allergens, significantly improving air quality. The unit can eliminate 99.99% of fine dust particles as small as 0.3 microns, including harmful PM2.5 indoor pollutants.
Kosmen KM-30N integrates many outstanding features
Clothes Drying
Dries clothes using moisture-separated airflow while maintaining room humidity, preventing moisture from returning to clothes. Clothes are dried effectively without overdrying or fading fabric colors.
Negative Ion Purification
Releases negative ions to remove airborne dust, maintaining a fresh and clean indoor atmosphere.
In addition, the machine is also equipped with several other features such as: humidity setting, HEPA air filtration, timer, child lock, water full alert, sleep mode, Wi-Fi connection, etc.
Wi-Fi Connection
Users can connect the device to Wi-Fi for easy remote control through the app. Once connected, you can customize settings, monitor ambient humidity, and set schedules conveniently via your smartphone.
How to Use
Upon first use, the machine enters standby mode. Press the Power button to start. The default mode is continuous dehumidification with low fan speed (indicator light on). If restarted, previous humidity settings will be retained.
Kosmen KM-30N air purifier and dehumidifier control panel
Power
Press the Power button to turn the unit ON/OFF.
HEPA
Press the Hepa button to enable/disable the air purification function. When this mode is active, dehumidification stops and the fan runs continuously for air filtration.
Anion
Press the Anion button to activate/deactivate the negative ion sterilization function.
Sleep Mode
Press and hold the Anion button for 5 seconds to activate/deactivate Sleep Mode. In this mode, all indicator lights turn off and humidity display is hidden.
Dry
Press the Dry button to enable/disable Clothes Drying Mode. This mode uses continuous dehumidification at high fan speed.
Note: Fan speed is fixed in Dry mode. To manually adjust humidity, press Dry again or press the HUM button.
Humidity
Press the Humidity button to set the desired humidity level. You can choose "CO" (Continuous Dehumidification) or set levels between 40%–70%, increasing by 10% with each press.
Child Lock
Press and hold the HUM button for 5 seconds to activate Child Lock. The display will show “LC”, and all buttons will be disabled. Hold again for 5 seconds to unlock and restore the humidity display.
Fan Speed
Press the Fan button to select High or Low fan speed.
Timer
Press the Timer button to activate the timer. The indicator will light up and the timer can be set between 1–24 hours. Press the button again until “00” appears. After eight flashes, the screen will return to the current humidity level, and the timer will deactivate.
Wi-Fi
Hold the Wi-Fi button for 5 seconds. When the Wi-Fi indicator blinks continuously, the device is ready to be paired with the mobile app.
Wi-Fi Connection Instructions
- Download the Smart Life or Tuya Smart app on your smartphone.
- Scan the QR code on the machine using the app and follow the instructions to connect to your Wi-Fi network.
- Important Notes:
- Ensure the dehumidifier, your phone, and the Wi-Fi router are close to each other during setup.
- Make sure your network is stable. The device only supports 2.4GHz Wi-Fi.
- Ensure the correct Wi-Fi password is entered.
- Follow the app's step-by-step instructions to complete the pairing.
Operation
How the Dehumidifier Works
- Compressor activates after 3-minute protection delay when room humidity ≥ (set humidity + 5% RH).
- Compressor stops when room humidity < (set humidity - 5% RH).
- Within the ±5% RH range, the unit maintains operation.
- The fan stops 3 minutes after humidity drops.
- When the water tank is full (3 beeps, indicator light on), the unit stops. Empty the tank and reinstall it properly to resume.
Defrosting
- After 30 minutes of operation, if the coil temperature is ≤ -1°C for 3 seconds, the compressor stops and the fan runs for defrosting.
- Defrost ends when coil temperature reaches ≥ 5°C for 3 minutes.
Indicator Lights
When a feature is activated, the corresponding button will be highlighted in green.
Power On/Off
When plugged in, the screen displays the current room humidity.
Press the Power button: if set humidity is at least 5% lower than room humidity, the unit starts operating.
HEPA Mode
- In HEPA mode, the compressor stops.
- The fan runs at default high speed.
- Press Fan to toggle between High and Low speed.
Full Tank
When the tank is full, the Full indicator turns red, the unit beeps 3 times, and stops operating.
Empty the tank and reinstall it properly to resume.
Usage Notes
- Follow national electrical standards and match power supply with the label specifications.
- Place the unit on a flat surface. Let it stand for 1 hour before plugging in if recently moved or tilted.
- Do not block air inlets/outlets. Indoor use only. Not suitable for closets, boats, or campers.
- Avoid circuit overload and prevent water from splashing onto the unit.
Some notes when using Kosmen KM-30N air purifier and dehumidifier
- Inspect the power cord and plug before use. Do not use the plug to turn the machine on/off.
- Always turn off, unplug, and empty the tank before moving the unit.
- Do not spray insecticides or flammable cleaners onto the unit.
- Children under 8 and persons with limited physical/mental capacity should only use the device under supervision.
- Only qualified technicians may service or repair the unit. Regular maintenance is recommended.
- Pre-Filter: Wash, dry completely, and reinstall.
- HEPA and Activated Carbon Filters: Non-washable. Replace every 6 months for optimal performance.
- Water Tank: Clean with cold/warm water. Do not use strong detergents or solvents to avoid damage.
- Continuous Drainage: Use the 11mm drain hose, do not immerse the hose end in water or bend the hose, as this may cause backflow and leaks.
- Water Level Float: Do not remove the float from the tank. If removed, the unit will not operate.
- Reinstalling Water Tank: Use both hands to push the tank securely into position. Misalignment may cause the unit to stop or overflow.
Error Code Table
Error Code | Error | Solution |
E1 | Temperature sensor error | Replace with a new temperature sensor |
E2 | Humidity sensor error | Replace with a new humidity sensor |
HI | Current humidity is too high (> 95%) | Close all doors and windows, then continue using the unit |
LO | Current humidity is too low (< 30%) | The current environment does not require dehumidification |
Troubleshooting
Please do not worry if you encounter the following issues while using the dehumidifier. If the device is damaged or malfunctions, please contact us promptly for assistance.
Issue | Symptoms / Causes | Solution |
Dehumidifier not operating | 1. Power outage 2. Power switch is off 3. Fuse may be blown 4. Device is in standby mode 5. Water tank is full or not installed correctly, water full indicator is flashing | 1. Wait for power to resume 2. Turn on the power 3. Replace the fuse 4. Cancel timer settings 5. Empty or reinstall the water tank and restart |
Dehumidifying performance is insufficient | 1. Incorrect humidity setting 2. Air inlet or outlet is blocked 3. Dehumidifier is not placed properly 4. Doors or windows are open 5. Room temperature is below 5°C or above 38°C | 1. Adjust to appropriate humidity setting 2. Remove obstructions 3. Ensure proper placement 4. Close all doors and windows 5. Use within the temperature range of 5–38°C |
Unit turns on and off after startup, no dehumidification | Turns off after 3 minutes due to compressor protection delay | The unit will resume operation after 3 minutes |
Water leakage | 1. Drain hose is loose 2. Drainage system is clogged 3. Water tank is not installed correctly | 1. Check the drain hose 2. Unclog the drainage system 3. Reinstall the water tank |
Condensation | Condensation on the surface of the dehumidifier | This is normal; the unit may defrost automatically |
Slight shaking or noise during operation | Slight rattling noise when turning on/off the unit | This is a normal phenomenon |
Specifications
Model | KM-30N |
Dehumidifying Capacity | 30 L/day (at 30°C, 80% RH) |
Power Supply | 220V 1phase |
Power Consumption | 355 W (with Hepa) |
Airflow Rate | 150 m3/ h (with Hepa) |
Compressor | Panasonic |
Refrigerant | R410A |
Operating Area | 70 - 105 ㎡ |
Filtration System | Pre-filter – HEPA filter (H13) – Carbon filter |
Functions | Dehumidification / Air Purification (HEPA) / Anion / Drying |
Water Tank Capacity | 5 liters |
Noise Level | ≤ 42dB (A) |
Working Environment | 5 - 35 ℃ 10% - 90% RH |
Product Dimensions | 370 * 270 * 630 mm |
Packaging Dimensions | 437 * 321 * 670 mm |
Net Weight | 15 Kg |
Gross Weight | 17 Kg |